Strong Starter Spring Starters
|
|
Hydraulic Starters
|
|
Flange Mounted
|
Direct Drive on Crank Shaft
|
System
|
Self-contained single unit starter motor + winding handle
|
Many Components Pump + Accelerator + cranking motor + control valve + reservoir + filter + piping
|
Many Components Pump + Accelerator + starting device + control valve + reservoir + filter + piping + pressure gauge + engine dog
|
Many Components Air supply valve + receiver + shut-off valve + lubricator + air filter + exhaust + air system + muffler + pressure gauge + piping + compressor
|
Mounting
|
Flange Mounted. Bolts on directly in place of electric starter. Winding adapter can be positioned in 8.5 degree steps for accessibility
|
Flange Mounted. Bolts on directly in place of electric starter but additional equipment must be accommodated. Winding adapter can be aligned in 4 different positions only
|
Mounted directly on end of crankshaft. Requires special support plate or engine casting. Shimming necessary to ensure correct clearance and concentricity
|
Flange or cradle mounted. electrical starter but additional equipment must be accommodated. Winding adapter can be aligned in 6 different positions only
|
Charging
|
Needs manual rewinding for each start.
Approx. 12 handle turns for each rewind.
|
Usually requires engine-driven pump. One charge sufficient for 10 engine turns.
Manual charging requires 110 turns on hand pump.
|
Usually requires engine-driven pump. One charge sufficient for 1 to 3 engine turns.
Manual charging requires approx. 70 turns on hand pump.
|
Requires air-compressor with 3 to 20 cu. Ft. of air pressure.
No manual charging option available.
|
Charging Times
|
~ 10 seconds for each start
|
Manual start may require 2--3 minutes to stroke the hand-pump. Engine-driven start may require a few minutes to start the pump and ~10 seconds afterwards for each start
|
Manual start may require upto 2 minutes to stroke the hand-pump. Engine-driven start may require a few minutes to start the pump and ~10 seconds afterwards for each start
|
Upto 20 minutes to start the air-compressor and ~10 seconds afterwards for each start.
|
Maintenance
|
None
|
Check for leaks. Ensure fluid levels are correct. Clamps must be secure. Check for leaks. Ensure checked if using engine-driven pump. Rubber hoses need to be checked air ingress. Extreme cleanliness required during maintenance.
|
Weekly - checks required for leaks. System should self-vent air ingress.
Monthly - check mountings and clean fuel tank filter. Check feed tank fluid level. Grease valve pivot.
Quarterly - remove starter and check operation.
Extreme cleanliness required during maintenance.
|
Needs permanent air line lubricators or weekly manual lubrication.
Check for leaks.
Check pressure regulator settings.
Check filters.
Compressor lubrication required periodically.
|
Weight
|
33Lbs to 50Lbs
|
11 to 40 Lbs for motor unit only. Extra weight for ancillary equipment. Total weight can be 150Lbs or more.
|
11 to 40 Lbs for motor unit only. Extra weight for ancillary equipment. Total weight can be 150Lbs or more.
|
16 to 60 Lbs for motor unit only. Extra weight for ancillary equipment. Total weight can be 150Lbs or more.
|
Potential Energy Losses
|
may weaken if left extremely long periods, but this has not been
|
Hydraulic oil leakage at pipe joints and seals
|
Hydraulic oil leakage at pipe joints and seals
|
Air leaks at pipe joints and seals
|